Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies
Atrium is a modern architectural design of buildings that has an open space at the middle and contains several floors. In atrium structure the smoke due to fire can easily flow through the open spaces and causes smoke contamination. CFD simulation using fire dynamic simulator (FDS) software is condu...
| Main Authors: | Mutafi, M.A., Nasif, M.S., Pao, W., Ismail, F.B. |
|---|---|
| Format: | Article |
| Institution: | Universiti Teknologi Petronas |
| Record Id / ISBN-0: | utp-eprints.19940 / |
| Published: |
Institute of Physics Publishing
2017
|
| Online Access: |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85034213606&doi=10.1088%2f1742-6596%2f908%2f1%2f012038&partnerID=40&md5=fadf303d5d07d1e422b4047784a09ac9 http://eprints.utp.edu.my/19940/ |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| id |
utp-eprints.19940 |
|---|---|
| recordtype |
eprints |
| spelling |
utp-eprints.199402018-04-22T13:47:06Z Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies Mutafi, M.A. Nasif, M.S. Pao, W. Ismail, F.B. Atrium is a modern architectural design of buildings that has an open space at the middle and contains several floors. In atrium structure the smoke due to fire can easily flow through the open spaces and causes smoke contamination. CFD simulation using fire dynamic simulator (FDS) software is conducted in this work, to investigate the effect of balcony open upstand on smoke contamination in atrium's balconies and compare it with balconies with solid upstand. It was found that in case of open upstand, the smoke contamination occurrence decreased inside the balcony comparing with balconies with solid upstand. © 2017 Published under licence by IOP Publishing Ltd. Institute of Physics Publishing 2017 Article PeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85034213606&doi=10.1088%2f1742-6596%2f908%2f1%2f012038&partnerID=40&md5=fadf303d5d07d1e422b4047784a09ac9 Mutafi, M.A. and Nasif, M.S. and Pao, W. and Ismail, F.B. (2017) Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies. Journal of Physics: Conference Series, 908 (1). http://eprints.utp.edu.my/19940/ |
| institution |
Universiti Teknologi Petronas |
| collection |
UTP Institutional Repository |
| description |
Atrium is a modern architectural design of buildings that has an open space at the middle and contains several floors. In atrium structure the smoke due to fire can easily flow through the open spaces and causes smoke contamination. CFD simulation using fire dynamic simulator (FDS) software is conducted in this work, to investigate the effect of balcony open upstand on smoke contamination in atrium's balconies and compare it with balconies with solid upstand. It was found that in case of open upstand, the smoke contamination occurrence decreased inside the balcony comparing with balconies with solid upstand. © 2017 Published under licence by IOP Publishing Ltd. |
| format |
Article |
| author |
Mutafi, M.A. Nasif, M.S. Pao, W. Ismail, F.B. |
| spellingShingle |
Mutafi, M.A. Nasif, M.S. Pao, W. Ismail, F.B. Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies |
| author_sort |
Mutafi, M.A. |
| title |
Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies |
| title_short |
Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies |
| title_full |
Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies |
| title_fullStr |
Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies |
| title_full_unstemmed |
Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies |
| title_sort |
numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies |
| publisher |
Institute of Physics Publishing |
| publishDate |
2017 |
| url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85034213606&doi=10.1088%2f1742-6596%2f908%2f1%2f012038&partnerID=40&md5=fadf303d5d07d1e422b4047784a09ac9 http://eprints.utp.edu.my/19940/ |
| _version_ |
1741196289205338112 |
| score |
11.62408 |