On the Influence of Collector Size on the Solar Chimneys Performance

Performance of solar chimney power plant system is highly influenced by the design geometries. The collector size is logically enhances the solar chimney performance, but the trend of enhancement is not yet investigated. In the present work, experimental and numerical investigations have been carrie...

Full description

Main Authors: Al-Azawiey, S.S., Al-Kayiem, H.H., Hassan, S.B.
Format: Article
Institution: Universiti Teknologi Petronas
Record Id / ISBN-0: utp-eprints.19979 /
Published: EDP Sciences 2017
Online Access: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85033236475&doi=10.1051%2fmatecconf%2f201713102011&partnerID=40&md5=cfabf511a47d651dec0700d7b302876e
http://eprints.utp.edu.my/19979/
Tags: Add Tag
No Tags, Be the first to tag this record!
id utp-eprints.19979
recordtype eprints
spelling utp-eprints.199792018-04-22T14:30:37Z On the Influence of Collector Size on the Solar Chimneys Performance Al-Azawiey, S.S. Al-Kayiem, H.H. Hassan, S.B. Performance of solar chimney power plant system is highly influenced by the design geometries. The collector size is logically enhances the solar chimney performance, but the trend of enhancement is not yet investigated. In the present work, experimental and numerical investigations have been carried out to ascertain, in terms of qualitative and quantitative evaluation, the effect of the collector diameter. Daily thermal efficiency has been determined at four different collector diameter. Two different collector diameters, 3.0 and 6.0 m, have been investigated experimentally, and then scaled up, to 9.0 and 12.0 m, by numerical simulation using ANSYS-FLUENT®15 software. Results demonstrated that collector diameter has effectively influenced the system performance. Larger collector diameter imposed increase in the velocity, temperature and the daily average thermal efficiency of the system. From the experimental results, increasing the collector diameter from 3.0 to 6.0 m has increased the daily average thermal efficiency of the collector from 9.81 to 12.8. Simulation results at 800 W/m2 irradiation revealed that the velocity in the chimney have increased from 1.66 m/s at 3.0 m collector diameter to 2.34, 2.47 and 2.63 m/s for 6.0, 9.0 and 12.0 m collector diameters, respectively. © The authors, published by EDP Sciences, 2017. EDP Sciences 2017 Article PeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85033236475&doi=10.1051%2fmatecconf%2f201713102011&partnerID=40&md5=cfabf511a47d651dec0700d7b302876e Al-Azawiey, S.S. and Al-Kayiem, H.H. and Hassan, S.B. (2017) On the Influence of Collector Size on the Solar Chimneys Performance. MATEC Web of Conferences, 131 . http://eprints.utp.edu.my/19979/
institution Universiti Teknologi Petronas
collection UTP Institutional Repository
description Performance of solar chimney power plant system is highly influenced by the design geometries. The collector size is logically enhances the solar chimney performance, but the trend of enhancement is not yet investigated. In the present work, experimental and numerical investigations have been carried out to ascertain, in terms of qualitative and quantitative evaluation, the effect of the collector diameter. Daily thermal efficiency has been determined at four different collector diameter. Two different collector diameters, 3.0 and 6.0 m, have been investigated experimentally, and then scaled up, to 9.0 and 12.0 m, by numerical simulation using ANSYS-FLUENT®15 software. Results demonstrated that collector diameter has effectively influenced the system performance. Larger collector diameter imposed increase in the velocity, temperature and the daily average thermal efficiency of the system. From the experimental results, increasing the collector diameter from 3.0 to 6.0 m has increased the daily average thermal efficiency of the collector from 9.81 to 12.8. Simulation results at 800 W/m2 irradiation revealed that the velocity in the chimney have increased from 1.66 m/s at 3.0 m collector diameter to 2.34, 2.47 and 2.63 m/s for 6.0, 9.0 and 12.0 m collector diameters, respectively. © The authors, published by EDP Sciences, 2017.
format Article
author Al-Azawiey, S.S.
Al-Kayiem, H.H.
Hassan, S.B.
spellingShingle Al-Azawiey, S.S.
Al-Kayiem, H.H.
Hassan, S.B.
On the Influence of Collector Size on the Solar Chimneys Performance
author_sort Al-Azawiey, S.S.
title On the Influence of Collector Size on the Solar Chimneys Performance
title_short On the Influence of Collector Size on the Solar Chimneys Performance
title_full On the Influence of Collector Size on the Solar Chimneys Performance
title_fullStr On the Influence of Collector Size on the Solar Chimneys Performance
title_full_unstemmed On the Influence of Collector Size on the Solar Chimneys Performance
title_sort on the influence of collector size on the solar chimneys performance
publisher EDP Sciences
publishDate 2017
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85033236475&doi=10.1051%2fmatecconf%2f201713102011&partnerID=40&md5=cfabf511a47d651dec0700d7b302876e
http://eprints.utp.edu.my/19979/
_version_ 1741196295854358528
score 11.62408