Sinusoid based calibration for holdup measurement in two-phase flow using helical capacitance sensor

A helical capacitance sensor was designed to measure the holdup of two-phase stratified flow in horizontal pipe. The structure of 360° twisted helical capacitance sensor had been designed, analyzed and optimized using finite element method. A sinusoidal function was observed as the relationship betw...

Full description

Main Authors: Lim, L.G., Tang, T.B., Hamid, N.H., Pao, W.K.S.
Format: Article
Institution: Universiti Teknologi Petronas
Record Id / ISBN-0: utp-eprints.20215 /
Published: Institute of Electrical and Electronics Engineers Inc. 2017
Online Access: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012024091&doi=10.1109%2fICIAS.2016.7824103&partnerID=40&md5=ed48c238178998b5ef6399268e01ff9d
http://eprints.utp.edu.my/20215/
Tags: Add Tag
No Tags, Be the first to tag this record!
id utp-eprints.20215
recordtype eprints
spelling utp-eprints.202152018-04-22T14:46:02Z Sinusoid based calibration for holdup measurement in two-phase flow using helical capacitance sensor Lim, L.G. Tang, T.B. Hamid, N.H. Pao, W.K.S. A helical capacitance sensor was designed to measure the holdup of two-phase stratified flow in horizontal pipe. The structure of 360° twisted helical capacitance sensor had been designed, analyzed and optimized using finite element method. A sinusoidal function was observed as the relationship between the capacitance readings and holdup. As the nonhomogeneity in the distribution of capacitance sensitivity field cannot be completely eliminated, a helical capacitance sensor was designed in such a way that a sinusoidal relationship was generated. The numerical readings and the approximation model obtained a very close agreement, where the mean absolute difference was about ±1. Besides, the effects of geometric parameters on the capacitance values were analyzed and investigated, where it was found that the symmetry of sinusoidal function can be modeled by adjusting the pitch of helix. © 2016 IEEE. Institute of Electrical and Electronics Engineers Inc. 2017 Article PeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012024091&doi=10.1109%2fICIAS.2016.7824103&partnerID=40&md5=ed48c238178998b5ef6399268e01ff9d Lim, L.G. and Tang, T.B. and Hamid, N.H. and Pao, W.K.S. (2017) Sinusoid based calibration for holdup measurement in two-phase flow using helical capacitance sensor. International Conference on Intelligent and Advanced Systems, ICIAS 2016 . http://eprints.utp.edu.my/20215/
institution Universiti Teknologi Petronas
collection UTP Institutional Repository
description A helical capacitance sensor was designed to measure the holdup of two-phase stratified flow in horizontal pipe. The structure of 360° twisted helical capacitance sensor had been designed, analyzed and optimized using finite element method. A sinusoidal function was observed as the relationship between the capacitance readings and holdup. As the nonhomogeneity in the distribution of capacitance sensitivity field cannot be completely eliminated, a helical capacitance sensor was designed in such a way that a sinusoidal relationship was generated. The numerical readings and the approximation model obtained a very close agreement, where the mean absolute difference was about ±1. Besides, the effects of geometric parameters on the capacitance values were analyzed and investigated, where it was found that the symmetry of sinusoidal function can be modeled by adjusting the pitch of helix. © 2016 IEEE.
format Article
author Lim, L.G.
Tang, T.B.
Hamid, N.H.
Pao, W.K.S.
spellingShingle Lim, L.G.
Tang, T.B.
Hamid, N.H.
Pao, W.K.S.
Sinusoid based calibration for holdup measurement in two-phase flow using helical capacitance sensor
author_sort Lim, L.G.
title Sinusoid based calibration for holdup measurement in two-phase flow using helical capacitance sensor
title_short Sinusoid based calibration for holdup measurement in two-phase flow using helical capacitance sensor
title_full Sinusoid based calibration for holdup measurement in two-phase flow using helical capacitance sensor
title_fullStr Sinusoid based calibration for holdup measurement in two-phase flow using helical capacitance sensor
title_full_unstemmed Sinusoid based calibration for holdup measurement in two-phase flow using helical capacitance sensor
title_sort sinusoid based calibration for holdup measurement in two-phase flow using helical capacitance sensor
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2017
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012024091&doi=10.1109%2fICIAS.2016.7824103&partnerID=40&md5=ed48c238178998b5ef6399268e01ff9d
http://eprints.utp.edu.my/20215/
_version_ 1741196336197271552
score 11.62408