Filtered feedback PID control for WirelessHART networked plant
The dynamism and portability of wireless installation allows for measurements to be obtained online in such environments hitherto considered challenging for wired measurements. WirelessHART standard has been in the open market for few years already. It has been acknowledged as a viable alternative t...
| Main Authors: | Abdullah, H., Ibrahim, R., Hassan, S.M., Chung, T.D. |
|---|---|
| Format: | Article |
| Institution: | Universiti Teknologi Petronas |
| Record Id / ISBN-0: | utp-eprints.20216 / |
| Published: |
Institute of Electrical and Electronics Engineers Inc.
2017
|
| Online Access: |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012034943&doi=10.1109%2fICIAS.2016.7824048&partnerID=40&md5=e7a5be1ce0133b4123789188c9ca1fde http://eprints.utp.edu.my/20216/ |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| id |
utp-eprints.20216 |
|---|---|
| recordtype |
eprints |
| spelling |
utp-eprints.202162018-04-22T14:46:02Z Filtered feedback PID control for WirelessHART networked plant Abdullah, H. Ibrahim, R. Hassan, S.M. Chung, T.D. The dynamism and portability of wireless installation allows for measurements to be obtained online in such environments hitherto considered challenging for wired measurements. WirelessHART standard has been in the open market for few years already. It has been acknowledged as a viable alternative to wired networks. By deploying wireless sensor network, the cost and period of wiring installation, maintenance and commissioning can be reduced. A Key issue associated with wireless networked control system is the packet dropout. This is prompted by the non-periodic update of measurements as a result of the use of wireless network in the control loop. The packet dropout can cause degradation and declining of the control performance and could possibly jeopardize plant safety. To overcome this phenomenon, this paper presents the application of filtered feedback PID control strategy. Analysis of the results obtained shows that the performance of the plant with the proposed method is better than the conventional PID control. © 2016 IEEE. Institute of Electrical and Electronics Engineers Inc. 2017 Article PeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012034943&doi=10.1109%2fICIAS.2016.7824048&partnerID=40&md5=e7a5be1ce0133b4123789188c9ca1fde Abdullah, H. and Ibrahim, R. and Hassan, S.M. and Chung, T.D. (2017) Filtered feedback PID control for WirelessHART networked plant. International Conference on Intelligent and Advanced Systems, ICIAS 2016 . http://eprints.utp.edu.my/20216/ |
| institution |
Universiti Teknologi Petronas |
| collection |
UTP Institutional Repository |
| description |
The dynamism and portability of wireless installation allows for measurements to be obtained online in such environments hitherto considered challenging for wired measurements. WirelessHART standard has been in the open market for few years already. It has been acknowledged as a viable alternative to wired networks. By deploying wireless sensor network, the cost and period of wiring installation, maintenance and commissioning can be reduced. A Key issue associated with wireless networked control system is the packet dropout. This is prompted by the non-periodic update of measurements as a result of the use of wireless network in the control loop. The packet dropout can cause degradation and declining of the control performance and could possibly jeopardize plant safety. To overcome this phenomenon, this paper presents the application of filtered feedback PID control strategy. Analysis of the results obtained shows that the performance of the plant with the proposed method is better than the conventional PID control. © 2016 IEEE. |
| format |
Article |
| author |
Abdullah, H. Ibrahim, R. Hassan, S.M. Chung, T.D. |
| spellingShingle |
Abdullah, H. Ibrahim, R. Hassan, S.M. Chung, T.D. Filtered feedback PID control for WirelessHART networked plant |
| author_sort |
Abdullah, H. |
| title |
Filtered feedback PID control for WirelessHART networked plant |
| title_short |
Filtered feedback PID control for WirelessHART networked plant |
| title_full |
Filtered feedback PID control for WirelessHART networked plant |
| title_fullStr |
Filtered feedback PID control for WirelessHART networked plant |
| title_full_unstemmed |
Filtered feedback PID control for WirelessHART networked plant |
| title_sort |
filtered feedback pid control for wirelesshart networked plant |
| publisher |
Institute of Electrical and Electronics Engineers Inc. |
| publishDate |
2017 |
| url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012034943&doi=10.1109%2fICIAS.2016.7824048&partnerID=40&md5=e7a5be1ce0133b4123789188c9ca1fde http://eprints.utp.edu.my/20216/ |
| _version_ |
1741196336354557952 |
| score |
11.62408 |