Error-reduction approach for corrosion measurements of pipeline inline inspection tools

Inline inspection tools that are used to scan the interior defects of gas and oil pipelines tend to suffer from measuring error due to their sizing accuracy. This error often causes an over- or under-estimation of the operating conditions of the pipeline, which might lead to a system failure. While...

Full description

Main Authors: Hamed, Y., Shafie, A., Mustaffa, Z., Rusma, N.
Format: Article
Institution: Universiti Teknologi Petronas
Record Id / ISBN-0: utp-eprints.22226 /
Published: 2019
Online Access: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85059346546&doi=10.1177%2f0020294018813643&partnerID=40&md5=75660d49b261f144a36cfc6707df2fe3
http://eprints.utp.edu.my/22226/
Tags: Add Tag
No Tags, Be the first to tag this record!
id utp-eprints.22226
recordtype eprints
spelling utp-eprints.222262019-02-28T02:51:12Z Error-reduction approach for corrosion measurements of pipeline inline inspection tools Hamed, Y. Shafie, A. Mustaffa, Z. Rusma, N. Inline inspection tools that are used to scan the interior defects of gas and oil pipelines tend to suffer from measuring error due to their sizing accuracy. This error often causes an over- or under-estimation of the operating conditions of the pipeline, which might lead to a system failure. While parametric calibration models provide a simple method to reduce the measuring error, it is limited to datasets that follow the normal distribution only. Thus, in this paper, a non-parametric calibration model based on k-nearest neighbor interpolation was proposed to improve the measurements recorded by the scanning tools. Corrosion data collected using an ultrasonic scan device and the magnetic flux leakage intelligent pig are considered in the research. The k-nearest neighbor interpolation is studied based on the effect of using six kernel functions with two different positioning approaches on the interpolation behavior. The results have shown enhancement in the accuracy of the readings obtained from the intelligent pig from ±20 of the pipeline wall thickness to only ±8. This enhancement in the sizing accuracy is meant to prevent a possible system failure for using the corroded part of the studied pipeline for an extra 4.6 years instead of replacing it. © The Author(s) 2018. 2019 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85059346546&doi=10.1177%2f0020294018813643&partnerID=40&md5=75660d49b261f144a36cfc6707df2fe3 Hamed, Y. and Shafie, A. and Mustaffa, Z. and Rusma, N. (2019) Error-reduction approach for corrosion measurements of pipeline inline inspection tools. Measurement and Control (United Kingdom), 52 (1-2). pp. 28-36. http://eprints.utp.edu.my/22226/
institution Universiti Teknologi Petronas
collection UTP Institutional Repository
description Inline inspection tools that are used to scan the interior defects of gas and oil pipelines tend to suffer from measuring error due to their sizing accuracy. This error often causes an over- or under-estimation of the operating conditions of the pipeline, which might lead to a system failure. While parametric calibration models provide a simple method to reduce the measuring error, it is limited to datasets that follow the normal distribution only. Thus, in this paper, a non-parametric calibration model based on k-nearest neighbor interpolation was proposed to improve the measurements recorded by the scanning tools. Corrosion data collected using an ultrasonic scan device and the magnetic flux leakage intelligent pig are considered in the research. The k-nearest neighbor interpolation is studied based on the effect of using six kernel functions with two different positioning approaches on the interpolation behavior. The results have shown enhancement in the accuracy of the readings obtained from the intelligent pig from ±20 of the pipeline wall thickness to only ±8. This enhancement in the sizing accuracy is meant to prevent a possible system failure for using the corroded part of the studied pipeline for an extra 4.6 years instead of replacing it. © The Author(s) 2018.
format Article
author Hamed, Y.
Shafie, A.
Mustaffa, Z.
Rusma, N.
spellingShingle Hamed, Y.
Shafie, A.
Mustaffa, Z.
Rusma, N.
Error-reduction approach for corrosion measurements of pipeline inline inspection tools
author_sort Hamed, Y.
title Error-reduction approach for corrosion measurements of pipeline inline inspection tools
title_short Error-reduction approach for corrosion measurements of pipeline inline inspection tools
title_full Error-reduction approach for corrosion measurements of pipeline inline inspection tools
title_fullStr Error-reduction approach for corrosion measurements of pipeline inline inspection tools
title_full_unstemmed Error-reduction approach for corrosion measurements of pipeline inline inspection tools
title_sort error-reduction approach for corrosion measurements of pipeline inline inspection tools
publishDate 2019
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85059346546&doi=10.1177%2f0020294018813643&partnerID=40&md5=75660d49b261f144a36cfc6707df2fe3
http://eprints.utp.edu.my/22226/
_version_ 1741196588056838144
score 11.62408