Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle

Human knee is an important joint in human body that allows leg movement. However, the cartilage can lose their shape and damage the bone due to illness. Total knee replacement is a medical procedure that replaced the bones with knee implant. However, difference in anatomy between Caucasian and Asian...

Full description

Main Authors: Fua-Nizan, R., Rani, A.M.A., Din, M.Y., Chopra, S.
Format: Article
Institution: Universiti Teknologi Petronas
Record Id / ISBN-0: utp-eprints.24764 /
Published: Springer 2020
Online Access: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85075721312&doi=10.1007%2f978-981-13-8297-0_3&partnerID=40&md5=de22d2a97a9681fd164f4b2828fd2b16
http://eprints.utp.edu.my/24764/
Tags: Add Tag
No Tags, Be the first to tag this record!
id utp-eprints.24764
recordtype eprints
spelling utp-eprints.247642021-08-27T05:33:05Z Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle Fua-Nizan, R. Rani, A.M.A. Din, M.Y. Chopra, S. Human knee is an important joint in human body that allows leg movement. However, the cartilage can lose their shape and damage the bone due to illness. Total knee replacement is a medical procedure that replaced the bones with knee implant. However, difference in anatomy between Caucasian and Asian has caused some concern in the fit of the knee implant and most knee implants in the market were not designed for greater flexion ability of Asian population. Hence, a customized femoral component for high flexion application was designed and analysed utilizing DICOM image of MRI scanned knee. Stress distribution analysis was conducted on the femoral component to study the effect of high flexion on the modified femoral component. Preliminary results showed that the stress distribution was relatively higher at smaller contact area. The result concluded that there was a possibility of failure on the modified femoral component due to high stress concentration. © 2020, Springer Nature Singapore Pte Ltd. Springer 2020 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85075721312&doi=10.1007%2f978-981-13-8297-0_3&partnerID=40&md5=de22d2a97a9681fd164f4b2828fd2b16 Fua-Nizan, R. and Rani, A.M.A. and Din, M.Y. and Chopra, S. (2020) Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle. Lecture Notes in Mechanical Engineering . pp. 17-22. http://eprints.utp.edu.my/24764/
institution Universiti Teknologi Petronas
collection UTP Institutional Repository
description Human knee is an important joint in human body that allows leg movement. However, the cartilage can lose their shape and damage the bone due to illness. Total knee replacement is a medical procedure that replaced the bones with knee implant. However, difference in anatomy between Caucasian and Asian has caused some concern in the fit of the knee implant and most knee implants in the market were not designed for greater flexion ability of Asian population. Hence, a customized femoral component for high flexion application was designed and analysed utilizing DICOM image of MRI scanned knee. Stress distribution analysis was conducted on the femoral component to study the effect of high flexion on the modified femoral component. Preliminary results showed that the stress distribution was relatively higher at smaller contact area. The result concluded that there was a possibility of failure on the modified femoral component due to high stress concentration. © 2020, Springer Nature Singapore Pte Ltd.
format Article
author Fua-Nizan, R.
Rani, A.M.A.
Din, M.Y.
Chopra, S.
spellingShingle Fua-Nizan, R.
Rani, A.M.A.
Din, M.Y.
Chopra, S.
Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle
author_sort Fua-Nizan, R.
title Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle
title_short Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle
title_full Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle
title_fullStr Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle
title_full_unstemmed Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle
title_sort preliminary study of stress distribution on modified femoral component of knee implant at maximum flexion angle
publisher Springer
publishDate 2020
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85075721312&doi=10.1007%2f978-981-13-8297-0_3&partnerID=40&md5=de22d2a97a9681fd164f4b2828fd2b16
http://eprints.utp.edu.my/24764/
_version_ 1741196865038188544
score 11.62408