Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle
Human knee is an important joint in human body that allows leg movement. However, the cartilage can lose their shape and damage the bone due to illness. Total knee replacement is a medical procedure that replaced the bones with knee implant. However, difference in anatomy between Caucasian and Asian...
| Main Authors: | Fua-Nizan, R., Rani, A.M.A., Din, M.Y., Chopra, S. |
|---|---|
| Format: | Article |
| Institution: | Universiti Teknologi Petronas |
| Record Id / ISBN-0: | utp-eprints.24764 / |
| Published: |
Springer
2020
|
| Online Access: |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85075721312&doi=10.1007%2f978-981-13-8297-0_3&partnerID=40&md5=de22d2a97a9681fd164f4b2828fd2b16 http://eprints.utp.edu.my/24764/ |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| id |
utp-eprints.24764 |
|---|---|
| recordtype |
eprints |
| spelling |
utp-eprints.247642021-08-27T05:33:05Z Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle Fua-Nizan, R. Rani, A.M.A. Din, M.Y. Chopra, S. Human knee is an important joint in human body that allows leg movement. However, the cartilage can lose their shape and damage the bone due to illness. Total knee replacement is a medical procedure that replaced the bones with knee implant. However, difference in anatomy between Caucasian and Asian has caused some concern in the fit of the knee implant and most knee implants in the market were not designed for greater flexion ability of Asian population. Hence, a customized femoral component for high flexion application was designed and analysed utilizing DICOM image of MRI scanned knee. Stress distribution analysis was conducted on the femoral component to study the effect of high flexion on the modified femoral component. Preliminary results showed that the stress distribution was relatively higher at smaller contact area. The result concluded that there was a possibility of failure on the modified femoral component due to high stress concentration. © 2020, Springer Nature Singapore Pte Ltd. Springer 2020 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85075721312&doi=10.1007%2f978-981-13-8297-0_3&partnerID=40&md5=de22d2a97a9681fd164f4b2828fd2b16 Fua-Nizan, R. and Rani, A.M.A. and Din, M.Y. and Chopra, S. (2020) Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle. Lecture Notes in Mechanical Engineering . pp. 17-22. http://eprints.utp.edu.my/24764/ |
| institution |
Universiti Teknologi Petronas |
| collection |
UTP Institutional Repository |
| description |
Human knee is an important joint in human body that allows leg movement. However, the cartilage can lose their shape and damage the bone due to illness. Total knee replacement is a medical procedure that replaced the bones with knee implant. However, difference in anatomy between Caucasian and Asian has caused some concern in the fit of the knee implant and most knee implants in the market were not designed for greater flexion ability of Asian population. Hence, a customized femoral component for high flexion application was designed and analysed utilizing DICOM image of MRI scanned knee. Stress distribution analysis was conducted on the femoral component to study the effect of high flexion on the modified femoral component. Preliminary results showed that the stress distribution was relatively higher at smaller contact area. The result concluded that there was a possibility of failure on the modified femoral component due to high stress concentration. © 2020, Springer Nature Singapore Pte Ltd. |
| format |
Article |
| author |
Fua-Nizan, R. Rani, A.M.A. Din, M.Y. Chopra, S. |
| spellingShingle |
Fua-Nizan, R. Rani, A.M.A. Din, M.Y. Chopra, S. Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle |
| author_sort |
Fua-Nizan, R. |
| title |
Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle |
| title_short |
Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle |
| title_full |
Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle |
| title_fullStr |
Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle |
| title_full_unstemmed |
Preliminary Study of Stress Distribution on Modified Femoral Component of Knee Implant at Maximum Flexion Angle |
| title_sort |
preliminary study of stress distribution on modified femoral component of knee implant at maximum flexion angle |
| publisher |
Springer |
| publishDate |
2020 |
| url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85075721312&doi=10.1007%2f978-981-13-8297-0_3&partnerID=40&md5=de22d2a97a9681fd164f4b2828fd2b16 http://eprints.utp.edu.my/24764/ |
| _version_ |
1741196865038188544 |
| score |
11.62408 |