Thermal and hydraulic analysis of a novel double-pipe geothermal heat exchanger with a controlled fractured zone at the well bottom

This study introduces a novel concept of semi closed-loop double-pipe heat exchangers with a controlled fractured zone at the well bottom to improve the geothermal heat extraction. The proposed model is benefitted from the reliable design of a double-pipe and the higher heat extraction rate of open...

Full description

Main Authors: Agson-Gani, P.H., Zueter, A.F., Xu, M., Ghoreishi-Madiseh, S.A., Kurnia, J.C., Sasmito, A.P.
Format: Article
Institution: Universiti Teknologi Petronas
Record Id / ISBN-0: utp-eprints.28609 /
Published: Elsevier Ltd 2022
Online Access: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85122968804&doi=10.1016%2fj.apenergy.2021.118407&partnerID=40&md5=b4f8d8082a2b96fdf079e62dd841fec1
http://eprints.utp.edu.my/28609/
Tags: Add Tag
No Tags, Be the first to tag this record!
id utp-eprints.28609
recordtype eprints
spelling utp-eprints.286092022-03-31T12:01:49Z Thermal and hydraulic analysis of a novel double-pipe geothermal heat exchanger with a controlled fractured zone at the well bottom Agson-Gani, P.H. Zueter, A.F. Xu, M. Ghoreishi-Madiseh, S.A. Kurnia, J.C. Sasmito, A.P. This study introduces a novel concept of semi closed-loop double-pipe heat exchangers with a controlled fractured zone at the well bottom to improve the geothermal heat extraction. The proposed model is benefitted from the reliable design of a double-pipe and the higher heat extraction rate of open geothermal systems. A conjugate mathematical model is developed and validated to simulate geothermal heat extraction, while the fractured zone is calculated by implementing the fractal theory. The results suggest that the proposed model can significantly improve the heat extraction rate and thermal power by up to more than 90, with an additional 28 of pumping power. Several operating parameters of the fractured zone are also evaluated, indicating that the increase of the heat extraction rate compared to the closed-loop model was within the range of 48�144 based on its design. Overall, this novel design shows the potential to improve the thermal and hydraulic performances of the conventional closed-loop geothermal system. © 2022 Elsevier Ltd 2022 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85122968804&doi=10.1016%2fj.apenergy.2021.118407&partnerID=40&md5=b4f8d8082a2b96fdf079e62dd841fec1 Agson-Gani, P.H. and Zueter, A.F. and Xu, M. and Ghoreishi-Madiseh, S.A. and Kurnia, J.C. and Sasmito, A.P. (2022) Thermal and hydraulic analysis of a novel double-pipe geothermal heat exchanger with a controlled fractured zone at the well bottom. Applied Energy, 310 . http://eprints.utp.edu.my/28609/
institution Universiti Teknologi Petronas
collection UTP Institutional Repository
description This study introduces a novel concept of semi closed-loop double-pipe heat exchangers with a controlled fractured zone at the well bottom to improve the geothermal heat extraction. The proposed model is benefitted from the reliable design of a double-pipe and the higher heat extraction rate of open geothermal systems. A conjugate mathematical model is developed and validated to simulate geothermal heat extraction, while the fractured zone is calculated by implementing the fractal theory. The results suggest that the proposed model can significantly improve the heat extraction rate and thermal power by up to more than 90, with an additional 28 of pumping power. Several operating parameters of the fractured zone are also evaluated, indicating that the increase of the heat extraction rate compared to the closed-loop model was within the range of 48�144 based on its design. Overall, this novel design shows the potential to improve the thermal and hydraulic performances of the conventional closed-loop geothermal system. © 2022
format Article
author Agson-Gani, P.H.
Zueter, A.F.
Xu, M.
Ghoreishi-Madiseh, S.A.
Kurnia, J.C.
Sasmito, A.P.
spellingShingle Agson-Gani, P.H.
Zueter, A.F.
Xu, M.
Ghoreishi-Madiseh, S.A.
Kurnia, J.C.
Sasmito, A.P.
Thermal and hydraulic analysis of a novel double-pipe geothermal heat exchanger with a controlled fractured zone at the well bottom
author_sort Agson-Gani, P.H.
title Thermal and hydraulic analysis of a novel double-pipe geothermal heat exchanger with a controlled fractured zone at the well bottom
title_short Thermal and hydraulic analysis of a novel double-pipe geothermal heat exchanger with a controlled fractured zone at the well bottom
title_full Thermal and hydraulic analysis of a novel double-pipe geothermal heat exchanger with a controlled fractured zone at the well bottom
title_fullStr Thermal and hydraulic analysis of a novel double-pipe geothermal heat exchanger with a controlled fractured zone at the well bottom
title_full_unstemmed Thermal and hydraulic analysis of a novel double-pipe geothermal heat exchanger with a controlled fractured zone at the well bottom
title_sort thermal and hydraulic analysis of a novel double-pipe geothermal heat exchanger with a controlled fractured zone at the well bottom
publisher Elsevier Ltd
publishDate 2022
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85122968804&doi=10.1016%2fj.apenergy.2021.118407&partnerID=40&md5=b4f8d8082a2b96fdf079e62dd841fec1
http://eprints.utp.edu.my/28609/
_version_ 1741197129457598464
score 11.62408