Determination of Three Endocrine Disruptors in Water Samples by Ultrasound-Assisted Salt-Induced Liquid-Liquid Microextraction (UA-SI-LLME) and High-Performance Liquid Chromatography�Diode Array Detection (HPLC-DAD)
Endocrine-disrupting compounds are routinely detected in environmental water. In this study, a simple and rapid sample preparation method based on ultrasound-assisted salt-induced liquid-liquid microextraction (UA-SI-LLME) followed by high performance liquid chromatography�diode array detection (H...
| Main Authors: | Rozaini, M.N.H., Saad, B., Yahaya, N., Lim, J.W., Mohd Aris, M.N., Ramachandran, M.R. |
|---|---|
| Format: | Article |
| Institution: | Universiti Teknologi Petronas |
| Record Id / ISBN-0: | utp-eprints.28828 / |
| Published: |
Taylor and Francis Ltd.
2022
|
| Online Access: |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85106048229&doi=10.1080%2f00032719.2021.1919691&partnerID=40&md5=99bca6089af6dce8d4b978af059f1588 http://eprints.utp.edu.my/28828/ |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| id |
utp-eprints.28828 |
|---|---|
| recordtype |
eprints |
| spelling |
utp-eprints.288282022-03-17T02:31:51Z Determination of Three Endocrine Disruptors in Water Samples by Ultrasound-Assisted Salt-Induced Liquid-Liquid Microextraction (UA-SI-LLME) and High-Performance Liquid Chromatography�Diode Array Detection (HPLC-DAD) Rozaini, M.N.H. Saad, B. Yahaya, N. Lim, J.W. Mohd Aris, M.N. Ramachandran, M.R. Endocrine-disrupting compounds are routinely detected in environmental water. In this study, a simple and rapid sample preparation method based on ultrasound-assisted salt-induced liquid-liquid microextraction (UA-SI-LLME) followed by high performance liquid chromatography�diode array detection (HPLC-DAD) was developed for the determination of triclosan, triclocarban and methyl-triclosan in water. Parameters that affect the extraction efficiency�such as type and mass of salt, type and volume of extraction solvent, extraction time, sample pH and sample volume�were studied. Under the optimized conditions, the method demonstrated linearity from 0.18 to 1000 µg L�1 with coefficients of determination R2 � 0.9899, limits of detection from 0.05 to 0.2 µg L�1, and good recoveries (> 70) with relative standard deviations < 10. The method was applied for the determination of triclosan, triclocarban, and methyl-triclosan in swimming pool, lake, and wastewater. The greenness of the method was quantified using the Analytical Eco-Scale Index. © 2022 Taylor & Francis Group, LLC. Taylor and Francis Ltd. 2022 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85106048229&doi=10.1080%2f00032719.2021.1919691&partnerID=40&md5=99bca6089af6dce8d4b978af059f1588 Rozaini, M.N.H. and Saad, B. and Yahaya, N. and Lim, J.W. and Mohd Aris, M.N. and Ramachandran, M.R. (2022) Determination of Three Endocrine Disruptors in Water Samples by Ultrasound-Assisted Salt-Induced Liquid-Liquid Microextraction (UA-SI-LLME) and High-Performance Liquid Chromatography�Diode Array Detection (HPLC-DAD). Analytical Letters, 55 (1). pp. 132-145. http://eprints.utp.edu.my/28828/ |
| institution |
Universiti Teknologi Petronas |
| collection |
UTP Institutional Repository |
| description |
Endocrine-disrupting compounds are routinely detected in environmental water. In this study, a simple and rapid sample preparation method based on ultrasound-assisted salt-induced liquid-liquid microextraction (UA-SI-LLME) followed by high performance liquid chromatography�diode array detection (HPLC-DAD) was developed for the determination of triclosan, triclocarban and methyl-triclosan in water. Parameters that affect the extraction efficiency�such as type and mass of salt, type and volume of extraction solvent, extraction time, sample pH and sample volume�were studied. Under the optimized conditions, the method demonstrated linearity from 0.18 to 1000 µg L�1 with coefficients of determination R2 � 0.9899, limits of detection from 0.05 to 0.2 µg L�1, and good recoveries (> 70) with relative standard deviations < 10. The method was applied for the determination of triclosan, triclocarban, and methyl-triclosan in swimming pool, lake, and wastewater. The greenness of the method was quantified using the Analytical Eco-Scale Index. © 2022 Taylor & Francis Group, LLC. |
| format |
Article |
| author |
Rozaini, M.N.H. Saad, B. Yahaya, N. Lim, J.W. Mohd Aris, M.N. Ramachandran, M.R. |
| spellingShingle |
Rozaini, M.N.H. Saad, B. Yahaya, N. Lim, J.W. Mohd Aris, M.N. Ramachandran, M.R. Determination of Three Endocrine Disruptors in Water Samples by Ultrasound-Assisted Salt-Induced Liquid-Liquid Microextraction (UA-SI-LLME) and High-Performance Liquid Chromatography�Diode Array Detection (HPLC-DAD) |
| author_sort |
Rozaini, M.N.H. |
| title |
Determination of Three Endocrine Disruptors in Water Samples by Ultrasound-Assisted Salt-Induced Liquid-Liquid Microextraction (UA-SI-LLME) and High-Performance Liquid Chromatography�Diode Array Detection (HPLC-DAD) |
| title_short |
Determination of Three Endocrine Disruptors in Water Samples by Ultrasound-Assisted Salt-Induced Liquid-Liquid Microextraction (UA-SI-LLME) and High-Performance Liquid Chromatography�Diode Array Detection (HPLC-DAD) |
| title_full |
Determination of Three Endocrine Disruptors in Water Samples by Ultrasound-Assisted Salt-Induced Liquid-Liquid Microextraction (UA-SI-LLME) and High-Performance Liquid Chromatography�Diode Array Detection (HPLC-DAD) |
| title_fullStr |
Determination of Three Endocrine Disruptors in Water Samples by Ultrasound-Assisted Salt-Induced Liquid-Liquid Microextraction (UA-SI-LLME) and High-Performance Liquid Chromatography�Diode Array Detection (HPLC-DAD) |
| title_full_unstemmed |
Determination of Three Endocrine Disruptors in Water Samples by Ultrasound-Assisted Salt-Induced Liquid-Liquid Microextraction (UA-SI-LLME) and High-Performance Liquid Chromatography�Diode Array Detection (HPLC-DAD) |
| title_sort |
determination of three endocrine disruptors in water samples by ultrasound-assisted salt-induced liquid-liquid microextraction (ua-si-llme) and high-performance liquid chromatography�diode array detection (hplc-dad) |
| publisher |
Taylor and Francis Ltd. |
| publishDate |
2022 |
| url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85106048229&doi=10.1080%2f00032719.2021.1919691&partnerID=40&md5=99bca6089af6dce8d4b978af059f1588 http://eprints.utp.edu.my/28828/ |
| _version_ |
1741197157837307904 |
| score |
11.62408 |