Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process

Hollow fiber membrane contactor (HFMC) has been widely studied for gas separation process due to its process intensification capability of combining conventional contactors with membrane technology. In the area of modeling and simulation of HFMC, the development of mathematical model for non-ideal c...

Full description

Main Authors: Ng, E.L.H., Lau, K.K., Lau, W.J., Ahmad, F.
Format: Article
Institution: Universiti Teknologi Petronas
Record Id / ISBN-0: utp-eprints.29562 /
Published: Korean Society of Industrial Engineering Chemistry 2021
Online Access: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85114751828&doi=10.1016%2fj.jiec.2021.08.028&partnerID=40&md5=467bea4a111b4d8a89f903801bb644d6
http://eprints.utp.edu.my/29562/
Tags: Add Tag
No Tags, Be the first to tag this record!
id utp-eprints.29562
recordtype eprints
spelling utp-eprints.295622022-03-25T02:09:06Z Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process Ng, E.L.H. Lau, K.K. Lau, W.J. Ahmad, F. Hollow fiber membrane contactor (HFMC) has been widely studied for gas separation process due to its process intensification capability of combining conventional contactors with membrane technology. In the area of modeling and simulation of HFMC, the development of mathematical model for non-ideal conditions, that is incorporated into process design is key to accurately reflect actual industrial gas separation process. This article aims to review the modelling and simulation techniques, the capabilities and the limitations of different mathematical models in predicting gas separation performance in HFMC for both laboratory analysis and industrial applications. The approach of incorporating the HFMC models into gas separation system and the current progress of process simulation works to develop industrial scale gas separation process will be highlighted. Future works and challenges towards developing comprehensive model in HFMC for industrial gas separation process would also be presented to portray the potential of modelling and simulation in designing and optimizing the HFMC system. © 2021 The Korean Society of Industrial and Engineering Chemistry Korean Society of Industrial Engineering Chemistry 2021 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85114751828&doi=10.1016%2fj.jiec.2021.08.028&partnerID=40&md5=467bea4a111b4d8a89f903801bb644d6 Ng, E.L.H. and Lau, K.K. and Lau, W.J. and Ahmad, F. (2021) Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process. Journal of Industrial and Engineering Chemistry, 104 . pp. 231-257. http://eprints.utp.edu.my/29562/
institution Universiti Teknologi Petronas
collection UTP Institutional Repository
description Hollow fiber membrane contactor (HFMC) has been widely studied for gas separation process due to its process intensification capability of combining conventional contactors with membrane technology. In the area of modeling and simulation of HFMC, the development of mathematical model for non-ideal conditions, that is incorporated into process design is key to accurately reflect actual industrial gas separation process. This article aims to review the modelling and simulation techniques, the capabilities and the limitations of different mathematical models in predicting gas separation performance in HFMC for both laboratory analysis and industrial applications. The approach of incorporating the HFMC models into gas separation system and the current progress of process simulation works to develop industrial scale gas separation process will be highlighted. Future works and challenges towards developing comprehensive model in HFMC for industrial gas separation process would also be presented to portray the potential of modelling and simulation in designing and optimizing the HFMC system. © 2021 The Korean Society of Industrial and Engineering Chemistry
format Article
author Ng, E.L.H.
Lau, K.K.
Lau, W.J.
Ahmad, F.
spellingShingle Ng, E.L.H.
Lau, K.K.
Lau, W.J.
Ahmad, F.
Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process
author_sort Ng, E.L.H.
title Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process
title_short Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process
title_full Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process
title_fullStr Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process
title_full_unstemmed Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process
title_sort holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process
publisher Korean Society of Industrial Engineering Chemistry
publishDate 2021
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85114751828&doi=10.1016%2fj.jiec.2021.08.028&partnerID=40&md5=467bea4a111b4d8a89f903801bb644d6
http://eprints.utp.edu.my/29562/
_version_ 1741197262541815808
score 11.62408