Optimization of oil palm-based cellulose and hydroxyapatite-carbon composite electrode for trace Pb(II) ions detection in aqueous system

An electroanalytical technique was devised using oil palm-based cellulose and hydroxyapatite as modifiers to carbon electrodes for Pb(II) ions detection in an aqueous system. The cyclic voltammetry scan suggested increased active binding sites and faster electron transfer with quasireversible redox...

Full description

Main Authors: Ajab, H., Yaqub, A., Nazir, M.S., Rozaini, M.Z.H., Abdullah, M.A.
Format: Article
Institution: Universiti Teknologi Petronas
Record Id / ISBN-0: utp-eprints.30104 /
Published: North Carolina State University 2020
Online Access: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85088474238&doi=10.15376%2fbiores.8.3.6273-6281&partnerID=40&md5=70727d74aa0ea6be4e7dbb05e95285a0
http://eprints.utp.edu.my/30104/
Tags: Add Tag
No Tags, Be the first to tag this record!
id utp-eprints.30104
recordtype eprints
spelling utp-eprints.301042022-03-25T06:34:25Z Optimization of oil palm-based cellulose and hydroxyapatite-carbon composite electrode for trace Pb(II) ions detection in aqueous system Ajab, H. Yaqub, A. Nazir, M.S. Rozaini, M.Z.H. Abdullah, M.A. An electroanalytical technique was devised using oil palm-based cellulose and hydroxyapatite as modifiers to carbon electrodes for Pb(II) ions detection in an aqueous system. The cyclic voltammetry scan suggested increased active binding sites and faster electron transfer with quasireversible redox peaks with a larger anodic current peak and smaller oxidation potential values. The optimal conditions were attained using 10 modifier at pH 2 in 0.1 M HCl,-1.2 V deposition potential, 270 s deposition time, 25 Hz frequency, 0.020 V amplitude, rotation speed of 700 rpm, and the step potential of 0.005 V. The square wave anodic stripping voltammetry established at optimum level exhibited excellent selectivity and stability from 10 ppb to 100 ppb for Pb(II) ions detection. Sharp anodic peaks were observed at-0.48 V for Pb(II) ions with the detection limit of 0.095 ± 0.32 ppb and limit of quantitation of 0.32 ± 0.32 ppb. © 2020 North Carolina State University. North Carolina State University 2020 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85088474238&doi=10.15376%2fbiores.8.3.6273-6281&partnerID=40&md5=70727d74aa0ea6be4e7dbb05e95285a0 Ajab, H. and Yaqub, A. and Nazir, M.S. and Rozaini, M.Z.H. and Abdullah, M.A. (2020) Optimization of oil palm-based cellulose and hydroxyapatite-carbon composite electrode for trace Pb(II) ions detection in aqueous system. BioResources, 15 (3). pp. 6273-6281. http://eprints.utp.edu.my/30104/
institution Universiti Teknologi Petronas
collection UTP Institutional Repository
description An electroanalytical technique was devised using oil palm-based cellulose and hydroxyapatite as modifiers to carbon electrodes for Pb(II) ions detection in an aqueous system. The cyclic voltammetry scan suggested increased active binding sites and faster electron transfer with quasireversible redox peaks with a larger anodic current peak and smaller oxidation potential values. The optimal conditions were attained using 10 modifier at pH 2 in 0.1 M HCl,-1.2 V deposition potential, 270 s deposition time, 25 Hz frequency, 0.020 V amplitude, rotation speed of 700 rpm, and the step potential of 0.005 V. The square wave anodic stripping voltammetry established at optimum level exhibited excellent selectivity and stability from 10 ppb to 100 ppb for Pb(II) ions detection. Sharp anodic peaks were observed at-0.48 V for Pb(II) ions with the detection limit of 0.095 ± 0.32 ppb and limit of quantitation of 0.32 ± 0.32 ppb. © 2020 North Carolina State University.
format Article
author Ajab, H.
Yaqub, A.
Nazir, M.S.
Rozaini, M.Z.H.
Abdullah, M.A.
spellingShingle Ajab, H.
Yaqub, A.
Nazir, M.S.
Rozaini, M.Z.H.
Abdullah, M.A.
Optimization of oil palm-based cellulose and hydroxyapatite-carbon composite electrode for trace Pb(II) ions detection in aqueous system
author_sort Ajab, H.
title Optimization of oil palm-based cellulose and hydroxyapatite-carbon composite electrode for trace Pb(II) ions detection in aqueous system
title_short Optimization of oil palm-based cellulose and hydroxyapatite-carbon composite electrode for trace Pb(II) ions detection in aqueous system
title_full Optimization of oil palm-based cellulose and hydroxyapatite-carbon composite electrode for trace Pb(II) ions detection in aqueous system
title_fullStr Optimization of oil palm-based cellulose and hydroxyapatite-carbon composite electrode for trace Pb(II) ions detection in aqueous system
title_full_unstemmed Optimization of oil palm-based cellulose and hydroxyapatite-carbon composite electrode for trace Pb(II) ions detection in aqueous system
title_sort optimization of oil palm-based cellulose and hydroxyapatite-carbon composite electrode for trace pb(ii) ions detection in aqueous system
publisher North Carolina State University
publishDate 2020
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85088474238&doi=10.15376%2fbiores.8.3.6273-6281&partnerID=40&md5=70727d74aa0ea6be4e7dbb05e95285a0
http://eprints.utp.edu.my/30104/
_version_ 1741197350524682240
score 11.62408