Roofing sheets systems for industrial sheds in cyclone prone areas based on dynamic testing

Rooing sheets of industrial sheds have been observed to fail in uplift under extreme wind conditions as in a cyclone. The ultimate loads from full scale static uplift load tests on asbestos cement and galvanized iron corrugated rooing sheet systems with different connections for span/purlin spacing...

Full description

Main Authors: Narayanan, S.P., Mathews, M.S.
Format: Article
Institution: Universiti Teknologi Petronas
Record Id / ISBN-0: utp-eprints.31064 /
Published: Construction Research Institute of Malaysia 2014
Online Access: https://www.scopus.com/inward/record.uri?eid=2-s2.0-84919769564&partnerID=40&md5=64923809cd1ffd6f1146403add399158
http://eprints.utp.edu.my/31064/
Tags: Add Tag
No Tags, Be the first to tag this record!
id utp-eprints.31064
recordtype eprints
spelling utp-eprints.310642022-03-25T08:53:55Z Roofing sheets systems for industrial sheds in cyclone prone areas based on dynamic testing Narayanan, S.P. Mathews, M.S. Rooing sheets of industrial sheds have been observed to fail in uplift under extreme wind conditions as in a cyclone. The ultimate loads from full scale static uplift load tests on asbestos cement and galvanized iron corrugated rooing sheet systems with different connections for span/purlin spacing of 1.4 m used in India using gravity load method were used to arrive at suitable connections for different wind zones. Since suitable rooing systems are not available for AC single span (case 1) and for Asbestos Cement (AC) and Corrugated Galvanized Iron (CGI) single and double span (case 2), static tests were done reduced spans and suitable spans were identiied. Fatigue is a major factor contributing to failure of rooing systems in the cyclone prone Eastern coastal zone. The rooing systems selected based on static tests were subjected to simulated dynamic tests which simulate low-high-low load cycles during a cyclone, ensuring that the frequency of load application does not coincide with natural frequency of rooing sheet system. If failure occurs, smaller spans are tested. For testing single and two span rooing sheets the two-point load systems and midspan load systems respectively were used. Based on the tests, suitable reduced spans are recommended for these zones. General guidelines to be followed while ixing AC and CGI rooing sheet systems are also given. Construction Research Institute of Malaysia 2014 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-84919769564&partnerID=40&md5=64923809cd1ffd6f1146403add399158 Narayanan, S.P. and Mathews, M.S. (2014) Roofing sheets systems for industrial sheds in cyclone prone areas based on dynamic testing. Malaysian Construction Research Journal, 14 (1). pp. 63-78. http://eprints.utp.edu.my/31064/
institution Universiti Teknologi Petronas
collection UTP Institutional Repository
description Rooing sheets of industrial sheds have been observed to fail in uplift under extreme wind conditions as in a cyclone. The ultimate loads from full scale static uplift load tests on asbestos cement and galvanized iron corrugated rooing sheet systems with different connections for span/purlin spacing of 1.4 m used in India using gravity load method were used to arrive at suitable connections for different wind zones. Since suitable rooing systems are not available for AC single span (case 1) and for Asbestos Cement (AC) and Corrugated Galvanized Iron (CGI) single and double span (case 2), static tests were done reduced spans and suitable spans were identiied. Fatigue is a major factor contributing to failure of rooing systems in the cyclone prone Eastern coastal zone. The rooing systems selected based on static tests were subjected to simulated dynamic tests which simulate low-high-low load cycles during a cyclone, ensuring that the frequency of load application does not coincide with natural frequency of rooing sheet system. If failure occurs, smaller spans are tested. For testing single and two span rooing sheets the two-point load systems and midspan load systems respectively were used. Based on the tests, suitable reduced spans are recommended for these zones. General guidelines to be followed while ixing AC and CGI rooing sheet systems are also given.
format Article
author Narayanan, S.P.
Mathews, M.S.
spellingShingle Narayanan, S.P.
Mathews, M.S.
Roofing sheets systems for industrial sheds in cyclone prone areas based on dynamic testing
author_sort Narayanan, S.P.
title Roofing sheets systems for industrial sheds in cyclone prone areas based on dynamic testing
title_short Roofing sheets systems for industrial sheds in cyclone prone areas based on dynamic testing
title_full Roofing sheets systems for industrial sheds in cyclone prone areas based on dynamic testing
title_fullStr Roofing sheets systems for industrial sheds in cyclone prone areas based on dynamic testing
title_full_unstemmed Roofing sheets systems for industrial sheds in cyclone prone areas based on dynamic testing
title_sort roofing sheets systems for industrial sheds in cyclone prone areas based on dynamic testing
publisher Construction Research Institute of Malaysia
publishDate 2014
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84919769564&partnerID=40&md5=64923809cd1ffd6f1146403add399158
http://eprints.utp.edu.my/31064/
_version_ 1741197513251094528
score 11.62408