Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies

This paper performed the effect of installing channel screen on smoke contamination in the presence of 0.5 m deep down stand in a fire compartment. The results are then compared with smoke contamination occurrence when the channel screens were removed. The results showed that there will be 96 increa...

Full description

Main Authors: Nasif, M.S., Hasnain, S.A., Pao, W., Al-Waked, R.
Format: Conference or Workshop Item
Institution: Universiti Teknologi Petronas
Record Id / ISBN-0: utp-eprints.32253 /
Published: EDP Sciences 2014
Online Access: https://www.scopus.com/inward/record.uri?eid=2-s2.0-84905002272&doi=10.1051%2fmatecconf%2f20141302007&partnerID=40&md5=6377a3e38804b71d170c443c6e6035ff
http://eprints.utp.edu.my/32253/
Tags: Add Tag
No Tags, Be the first to tag this record!
id utp-eprints.32253
recordtype eprints
spelling utp-eprints.322532022-03-29T05:02:25Z Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies Nasif, M.S. Hasnain, S.A. Pao, W. Al-Waked, R. This paper performed the effect of installing channel screen on smoke contamination in the presence of 0.5 m deep down stand in a fire compartment. The results are then compared with smoke contamination occurrence when the channel screens were removed. The results showed that there will be 96 increase in upper balconies smoke contamination in an atrium when no channel screens at fire compartment opening are used. This work provides new correlation obtained from numerical study which can predict the smoke contamination height in upper balconies of the atrium in the presence of 0.5 m down stand and no channel screens. The proposed correlation will be useful design tool for building designer to design safe shopping malls (atrium). © 2014 Owned by the authors, published by EDP Sciences. EDP Sciences 2014 Conference or Workshop Item NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-84905002272&doi=10.1051%2fmatecconf%2f20141302007&partnerID=40&md5=6377a3e38804b71d170c443c6e6035ff Nasif, M.S. and Hasnain, S.A. and Pao, W. and Al-Waked, R. (2014) Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies. In: UNSPECIFIED. http://eprints.utp.edu.my/32253/
institution Universiti Teknologi Petronas
collection UTP Institutional Repository
description This paper performed the effect of installing channel screen on smoke contamination in the presence of 0.5 m deep down stand in a fire compartment. The results are then compared with smoke contamination occurrence when the channel screens were removed. The results showed that there will be 96 increase in upper balconies smoke contamination in an atrium when no channel screens at fire compartment opening are used. This work provides new correlation obtained from numerical study which can predict the smoke contamination height in upper balconies of the atrium in the presence of 0.5 m down stand and no channel screens. The proposed correlation will be useful design tool for building designer to design safe shopping malls (atrium). © 2014 Owned by the authors, published by EDP Sciences.
format Conference or Workshop Item
author Nasif, M.S.
Hasnain, S.A.
Pao, W.
Al-Waked, R.
spellingShingle Nasif, M.S.
Hasnain, S.A.
Pao, W.
Al-Waked, R.
Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies
author_sort Nasif, M.S.
title Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies
title_short Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies
title_full Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies
title_fullStr Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies
title_full_unstemmed Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies
title_sort computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies
publisher EDP Sciences
publishDate 2014
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84905002272&doi=10.1051%2fmatecconf%2f20141302007&partnerID=40&md5=6377a3e38804b71d170c443c6e6035ff
http://eprints.utp.edu.my/32253/
_version_ 1741197707724193792
score 11.62408