Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies
This paper performed the effect of installing channel screen on smoke contamination in the presence of 0.5 m deep down stand in a fire compartment. The results are then compared with smoke contamination occurrence when the channel screens were removed. The results showed that there will be 96 increa...
| Main Authors: | Nasif, M.S., Hasnain, S.A., Pao, W., Al-Waked, R. |
|---|---|
| Format: | Conference or Workshop Item |
| Institution: | Universiti Teknologi Petronas |
| Record Id / ISBN-0: | utp-eprints.32253 / |
| Published: |
EDP Sciences
2014
|
| Online Access: |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84905002272&doi=10.1051%2fmatecconf%2f20141302007&partnerID=40&md5=6377a3e38804b71d170c443c6e6035ff http://eprints.utp.edu.my/32253/ |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| id |
utp-eprints.32253 |
|---|---|
| recordtype |
eprints |
| spelling |
utp-eprints.322532022-03-29T05:02:25Z Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies Nasif, M.S. Hasnain, S.A. Pao, W. Al-Waked, R. This paper performed the effect of installing channel screen on smoke contamination in the presence of 0.5 m deep down stand in a fire compartment. The results are then compared with smoke contamination occurrence when the channel screens were removed. The results showed that there will be 96 increase in upper balconies smoke contamination in an atrium when no channel screens at fire compartment opening are used. This work provides new correlation obtained from numerical study which can predict the smoke contamination height in upper balconies of the atrium in the presence of 0.5 m down stand and no channel screens. The proposed correlation will be useful design tool for building designer to design safe shopping malls (atrium). © 2014 Owned by the authors, published by EDP Sciences. EDP Sciences 2014 Conference or Workshop Item NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-84905002272&doi=10.1051%2fmatecconf%2f20141302007&partnerID=40&md5=6377a3e38804b71d170c443c6e6035ff Nasif, M.S. and Hasnain, S.A. and Pao, W. and Al-Waked, R. (2014) Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies. In: UNSPECIFIED. http://eprints.utp.edu.my/32253/ |
| institution |
Universiti Teknologi Petronas |
| collection |
UTP Institutional Repository |
| description |
This paper performed the effect of installing channel screen on smoke contamination in the presence of 0.5 m deep down stand in a fire compartment. The results are then compared with smoke contamination occurrence when the channel screens were removed. The results showed that there will be 96 increase in upper balconies smoke contamination in an atrium when no channel screens at fire compartment opening are used. This work provides new correlation obtained from numerical study which can predict the smoke contamination height in upper balconies of the atrium in the presence of 0.5 m down stand and no channel screens. The proposed correlation will be useful design tool for building designer to design safe shopping malls (atrium). © 2014 Owned by the authors, published by EDP Sciences. |
| format |
Conference or Workshop Item |
| author |
Nasif, M.S. Hasnain, S.A. Pao, W. Al-Waked, R. |
| spellingShingle |
Nasif, M.S. Hasnain, S.A. Pao, W. Al-Waked, R. Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies |
| author_sort |
Nasif, M.S. |
| title |
Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies |
| title_short |
Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies |
| title_full |
Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies |
| title_fullStr |
Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies |
| title_full_unstemmed |
Computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper Balconies |
| title_sort |
computer simulation investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies |
| publisher |
EDP Sciences |
| publishDate |
2014 |
| url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84905002272&doi=10.1051%2fmatecconf%2f20141302007&partnerID=40&md5=6377a3e38804b71d170c443c6e6035ff http://eprints.utp.edu.my/32253/ |
| _version_ |
1741197707724193792 |
| score |
11.62408 |