FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS

To ensure transformers still in working condition, it must be tested with few tests. DGA (Dissolve Gas Analysis) test, insulation test, FDS (Frequency Dielectric Spectroscopy) test and etc[1]. As for knowing the condition inside the transformer especially on a transformer core and winding, testing...

Full description

Main Author: ABU HASSAN, MUHAMMAD HUSAINI
Format: Final Year Project
Language: English
Institution: Universiti Teknologi Petronas
Record Id / ISBN-0: utp-utpedia.20169 /
Published: IRC 2019
Online Access: http://utpedia.utp.edu.my/20169/1/MuhammadHusainiFR_23194.pdf
http://utpedia.utp.edu.my/20169/
Tags: Add Tag
No Tags, Be the first to tag this record!
id utp-utpedia.20169
recordtype eprints
spelling utp-utpedia.201692019-12-20T16:13:40Z http://utpedia.utp.edu.my/20169/ FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS ABU HASSAN, MUHAMMAD HUSAINI To ensure transformers still in working condition, it must be tested with few tests. DGA (Dissolve Gas Analysis) test, insulation test, FDS (Frequency Dielectric Spectroscopy) test and etc[1]. As for knowing the condition inside the transformer especially on a transformer core and winding, testing the mechanical condition for both of it, we need FRA test. Frequency Response Analysis (FRA) or Sweep Frequency Response Analysis (SFRA) techniques have been gaining a lot of attention in analyzing the electrical winding and magnetic cores of power transformer throughout this decade[2]. As the test runs and being analyze, the localization of trending of faults is still in a depth of investigation. This research is focus on analyzing 5 testing method on transformer in finding and analyzing short circuit fault in the power transformer. IRC 2019-01 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/20169/1/MuhammadHusainiFR_23194.pdf ABU HASSAN, MUHAMMAD HUSAINI (2019) FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS. IRC, Universiti Teknologi PETRONAS. (Submitted)
institution Universiti Teknologi Petronas
collection UTPedia
language English
description To ensure transformers still in working condition, it must be tested with few tests. DGA (Dissolve Gas Analysis) test, insulation test, FDS (Frequency Dielectric Spectroscopy) test and etc[1]. As for knowing the condition inside the transformer especially on a transformer core and winding, testing the mechanical condition for both of it, we need FRA test. Frequency Response Analysis (FRA) or Sweep Frequency Response Analysis (SFRA) techniques have been gaining a lot of attention in analyzing the electrical winding and magnetic cores of power transformer throughout this decade[2]. As the test runs and being analyze, the localization of trending of faults is still in a depth of investigation. This research is focus on analyzing 5 testing method on transformer in finding and analyzing short circuit fault in the power transformer.
format Final Year Project
author ABU HASSAN, MUHAMMAD HUSAINI
spellingShingle ABU HASSAN, MUHAMMAD HUSAINI
FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS
author_sort ABU HASSAN, MUHAMMAD HUSAINI
title FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS
title_short FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS
title_full FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS
title_fullStr FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS
title_full_unstemmed FREQUENCY RESPONSE ANALYSIS FOR TRANSFORMERS
title_sort frequency response analysis for transformers
publisher IRC
publishDate 2019
url http://utpedia.utp.edu.my/20169/1/MuhammadHusainiFR_23194.pdf
http://utpedia.utp.edu.my/20169/
_version_ 1741195585701019648
score 11.62408