MODELLING OF PMio CONCENTRATIONS IN AN UNDERGROUND ENCLOSED LOADING DOCK IN MALAYSIA
The enclosed nature of underground loading docks and their limited contact with outdoor air will result in poor indoor air quality due to quick accumulation of motor vehiclesemissions. Concentrations ofmany harmful air pollutants includingPMio can increase and reach dangerous levels. PMio have be...
| Main Author: | ABUALQUMBOZ, MOTASEM S |
|---|---|
| Format: | Thesis |
| Language: | English |
| Institution: | Universiti Teknologi Petronas |
| Record Id / ISBN-0: | utp-utpedia.21663 / |
| Published: |
2016
|
| Subjects: | |
| Online Access: |
http://utpedia.utp.edu.my/21663/1/2016-CIVIL%20AND%20ENVIRONMENTAL-MODELLING%20OF%20PM10%20CONCENTRATIONS%20IN%20AN%20UNDERGROUND%20ENCLOSED%20LOADING%20DOCK%20IN%20MALAYSIA-MOTASEM%20S%20ABUALQUMBOZ.pdf http://utpedia.utp.edu.my/21663/ |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| id |
utp-utpedia.21663 |
|---|---|
| recordtype |
eprints |
| spelling |
utp-utpedia.216632021-09-23T23:21:54Z http://utpedia.utp.edu.my/21663/ MODELLING OF PMio CONCENTRATIONS IN AN UNDERGROUND ENCLOSED LOADING DOCK IN MALAYSIA ABUALQUMBOZ, MOTASEM S TA Engineering (General). Civil engineering (General) The enclosed nature of underground loading docks and their limited contact with outdoor air will result in poor indoor air quality due to quick accumulation of motor vehiclesemissions. Concentrations ofmany harmful air pollutants includingPMio can increase and reach dangerous levels. PMio have been attributed to increased mortality rates and respiratory and cardiovascular diseases. This study aims at modelling PMio concentrations in an underground loading dock located in Kuala Lumpur, Malaysia. Firstly, PMio concentrations were continuously measured inside the loading dock for 20 weeks using the real-time air quality monitoring instrument (AQM60) starting from November 8th, 2014. Secondly, a group of statistical tests were applied using the SPSS in order to evaluate the indoor air quality in term of PMio concentrations. 2016-05 Thesis NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/21663/1/2016-CIVIL%20AND%20ENVIRONMENTAL-MODELLING%20OF%20PM10%20CONCENTRATIONS%20IN%20AN%20UNDERGROUND%20ENCLOSED%20LOADING%20DOCK%20IN%20MALAYSIA-MOTASEM%20S%20ABUALQUMBOZ.pdf ABUALQUMBOZ, MOTASEM S (2016) MODELLING OF PMio CONCENTRATIONS IN AN UNDERGROUND ENCLOSED LOADING DOCK IN MALAYSIA. Masters thesis, Universiti Teknologi PETRONAS. |
| institution |
Universiti Teknologi Petronas |
| collection |
UTPedia |
| language |
English |
| topic |
TA Engineering (General). Civil engineering (General) |
| spellingShingle |
TA Engineering (General). Civil engineering (General) ABUALQUMBOZ, MOTASEM S MODELLING OF PMio CONCENTRATIONS IN AN UNDERGROUND ENCLOSED LOADING DOCK IN MALAYSIA |
| description |
The enclosed nature of underground loading docks and their limited contact with
outdoor air will result in poor indoor air quality due to quick accumulation of motor
vehiclesemissions. Concentrations ofmany harmful air pollutants includingPMio can
increase and reach dangerous levels. PMio have been attributed to increased mortality
rates and respiratory and cardiovascular diseases. This study aims at modelling PMio
concentrations in an underground loading dock located in Kuala Lumpur, Malaysia.
Firstly, PMio concentrations were continuously measured inside the loading dock for
20 weeks using the real-time air quality monitoring instrument (AQM60) starting from
November 8th, 2014. Secondly, a group of statistical tests were applied using the SPSS
in order to evaluate the indoor air quality in term of PMio concentrations. |
| format |
Thesis |
| author |
ABUALQUMBOZ, MOTASEM S |
| author_sort |
ABUALQUMBOZ, MOTASEM S |
| title |
MODELLING OF PMio CONCENTRATIONS IN AN UNDERGROUND
ENCLOSED LOADING DOCK IN MALAYSIA |
| title_short |
MODELLING OF PMio CONCENTRATIONS IN AN UNDERGROUND
ENCLOSED LOADING DOCK IN MALAYSIA |
| title_full |
MODELLING OF PMio CONCENTRATIONS IN AN UNDERGROUND
ENCLOSED LOADING DOCK IN MALAYSIA |
| title_fullStr |
MODELLING OF PMio CONCENTRATIONS IN AN UNDERGROUND
ENCLOSED LOADING DOCK IN MALAYSIA |
| title_full_unstemmed |
MODELLING OF PMio CONCENTRATIONS IN AN UNDERGROUND
ENCLOSED LOADING DOCK IN MALAYSIA |
| title_sort |
modelling of pmio concentrations in an underground
enclosed loading dock in malaysia |
| publishDate |
2016 |
| url |
http://utpedia.utp.edu.my/21663/1/2016-CIVIL%20AND%20ENVIRONMENTAL-MODELLING%20OF%20PM10%20CONCENTRATIONS%20IN%20AN%20UNDERGROUND%20ENCLOSED%20LOADING%20DOCK%20IN%20MALAYSIA-MOTASEM%20S%20ABUALQUMBOZ.pdf http://utpedia.utp.edu.my/21663/ |
| _version_ |
1741195769860325376 |
| score |
11.62408 |